Product Name : Medical battery
PN : 13051-215
Cell type : Li-ion
Condition : New
Voltage : 12V
Capacity : 2.6Ah
Energy : 38.48Wh
Cycle life : ≥300 times
Weight : About 320g
Size : 105mm×65mm×22mm
Charging time : 3-3.5hours
Nihon Kodhen original Cardiolife AED battery 13051-215
The original Cardiolife AED battery 13051-215 is a factory-designed rechargeable lithium-ion battery specifically developed for Cardiolife AEDs.
This battery features a 14.8V voltage and a 2600mAh capacity, designed to provide immediate and stable power support to AEDs in scenarios such as public places without a fixed power source and out-of-hospital emergency situations. It ensures rapid activation of critical functions such as automatic heart rhythm analysis and defibrillation shock, making it a key medical accessory for improving the success rate of resuscitation for cardiac arrest patients.
1. Emergency-Grade Instant Activation
Addressing the "second-level response" requirement of AEDs, the battery can instantly provide the current needed for defibrillation, supporting more than 10 consecutive defibrillation shocks or more than 4 hours of continuous standby time, providing full power for a single out-of-hospital emergency and avoiding power interruptions in critical moments.
2. Intelligent Status Monitoring
Built-in BMS displays the remaining battery power, battery health status, and remaining lifespan in real time on the AED main unit screen. Low battery triggers audible and visual alarms and screen prompts. It also features a periodic self-check function to ensure the AED is always ready for use, reducing manual maintenance costs.
3. Strong Environmental Adaptability
It can output stably in extreme environments ranging from -20℃ to 60℃, suitable for public emergency scenarios such as outdoor activities in northern winters, scorching summers in southern regions, and low temperatures at high altitudes, avoiding the impact of environmental temperature on defibrillation energy accuracy.
4. Tool-Free Quick Replacement
Utilizing a "slide-in + snap-lock" design, no tools are required. Ordinary people can complete the replacement within 10 seconds following voice guidance, suitable for emergency operations by non-professionals in public places, ensuring the device is quickly restored to standby status.
| Product name | battery |
| PN | 13051-215 |
| Cell type | Li-ion |
| Voltage | 12V |
| Capacity | 2.6Ah |
| Energy | 38.48Wh |
| Working current | 0.3-0.5A |
| Charge time | 3-3.5hours |
| Cycle life | ≥300 times |
| Storage lifespan | 12 months |
| Size | 105mm×65mm×22mm |
| Weight | About 320g |

Q1: My AED in a public place reports "Low Battery" but I don't have a spare battery. What should I do?
A1: In this situation, prioritize ensuring the core defibrillation function. Turn off other non-essential functions to extend the remaining usage time. Contact staff to replace the battery.
Q2: After 10 months of battery backup, the AED self-test indicates "Battery Life is Insufficient," but it can still support 8 defibrillations. Should I replace it immediately?
A2: The "Battery Life is Insufficient" message indicates that the battery is nearing the end of its backup life. If the battery is in a crowded public place, it is recommended to replace it immediately to avoid battery failure during an emergency. If it is in a less crowded setting such as a community, replacement can be arranged within one month, but you should manually trigger the self-test once a week to ensure the battery is in good condition.
Q3: When using battery power, the AED suddenly indicates "Insufficient Defibrillation Energy." Switching to the spare battery restores normal operation. Is this a problem with the original battery?
A3: It is highly likely that the original battery performance has deteriorated. If the battery has been used more than 200 times, it is due to capacity decay and the battery should be replaced. If the number of cycles is low and the interface is normal, it may be due to unbalanced cells, which indicates a battery malfunction. Please replace the battery in time to avoid accidents when using it in public places.
|
|